41 C.F.R. · Public Contracts and Property Management
41 C.F.R. § 102.80.115

Is there more than one option for establishing that an equivalent level of safety exists?

Title 41 C.F.R. ● ACTIVE Primary Source
Regulatory Text

41 C.F.R. § 102.80.115 — Is there more than one option for establishing that an equivalent level of safety exists?

§ 102–80.115 Is there more than one option for establishing that an equivalent level of safety exists? Yes, the following are three options for establishing that an equivalent level of safety exists: (a) In the first option, the margin of safety provided by various alternatives is compared to that obtained for a code complying building with complete sprinkler protection. The margin of safety is the difference between the available safe egress time and the required safe egress time. Available safe egress time is the time available for evacuation of occupants to an area of safety prior to the onset of untenable conditions in occupied areas or the egress pathways. The required safe egress time is the time required by occupants to move from their positions at the start of the fire to areas of safety. Available safe egress times would be developed based on analysis of a number of assumed reasonable worst case fire scenarios including assessment of a code complying fully sprinklered building. Additional analysis would be used to determine the expected required safe egress times for the various scenarios. If the margin of safety plus an appropriate safety factor is greater for an alternative than for the fully sprinklered building, then the alternative should provide an equivalent level of safety. (b) A second alternative is applicable for typical office and residential scenarios. In these situations, complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire size to no more than 1 megawatt (950 Btu/sec), and prevent flames from leaving the room of origin. The times required for each of these conditions to occur in the area of interest must be determined. The shortest of these three times would become the time available for escape. The difference between the minimum time available for escape and the time required for evacuation of building occupants would be the target margin of safety. Various alternative protection strategies would have to be evaluated to determine their impact on the times at which hazardous conditions developed in the spaces of interest and the times required for egress. If a combination of fire protection systems provides a margin of safety equal to or greater than the target margin of safety, then the combination could be judged to provide an equivalent level of safety. (c) As a third option, other technical analysis procedures, as approved by the responsible agency head, can be used to show equivalency.

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR41-SEC-61AA80
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
41 C.F.R. § 102.80.115
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
ea951542e0673289...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 41 C.F.R. § 102.80.115 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 41 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 41 41 C.F.R. § 102.80.115