46 C.F.R. § 98.30.37 — Firefighting requirements.
§ 98.30–37 Firefighting requirements. No person may lift a portable tank on or off a vessel, or transfer a product with a flashpoint of less than 300 °F to or from a portable tank or IBC unless— (a) Water pressure is maintained on the firemain; (b) Firehoses, fitted with a Coast Guard-approved combination nozzle, are attached to each fire hydrant in the vicinity of the portable tanks; (c) Except as provided in § 98.30–39, fire extinguishers of a dry chemical type are— (1) Located to protect the deck area 10 feet in any horizontal direction from each portable tank and its associated cargo handling system; (2) Coast Guard approved; and (3) Capable of covering the deck area without being moved; (d) In a deck area of 500 square feet or less, there are two or more dry chemical fire extinguishers of 300 pounds or more total capacity of extinguishing agent; and (e) In a deck area of more than 500 square feet, there are three or more dry chemical fire extinguishers of 450 pounds or more total capacity of extinguishing agent. [CGD 73–172, 39 FR 22954, June 25, 1974, as amended by USCG–2011–0088, 78 FR 54787, Sept. 6, 2013]