46 C.F.R. § 42.15.65 — Side scuttles.

§ 42.15-65 Side scuttles. (a) Side scuttles to spaces below the freeboard deck or to spaces within enclosed superstructures shall be fitted with efficient hinged inside deadlights arranged so that they can be effectively closed and secured watertight. (b) No side scuttle shall be fitted in a position so that its sill is below a line drawn parallel to the freeboard deck at side and having its lowest point 2.5 percent of the breadth ( B ) above the load waterline, or 19 1/2 inches, which ever is the greater distance. (c) The side scuttles, together with their glasses, if fitted, and deadlights, shall be of substantial and approved construction. [CGFR 68-60, 33 FR 10062, July 12, 1968]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR46-SEC-E287CF
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
46 C.F.R. § 42.15.65
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
3fe78b066d416047...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 46 C.F.R. § 42.15.65 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.