46 C.F.R. § 32.57.5 — Definitions-TB/ALL.

§ 32.57–5 Definitions—TB/ALL. (a) Standard fire test. A “standard fire test” is one which develops in the test furnace a series of time temperature relationships as follows:   5 minutes—1,000 °F.   10 minutes—1,300 °F.   30 minutes—1,550 °F.   60 minutes—1,700 °F. (b) “A” Class divisions. “A” Class divisions such as bulkheads and decks, means divisions that are composed of steel or an equivalent metal, suitably stiffened, and made intact with the main structure of the vessel, including the shell, structural bulkheads, or decks. They are constructed so that, if subjected to the standard fire test, they are capable of preventing the passage of flame and smoke for one hour. In addition, they are insulated with approved structural insulation, bulkhead panels, or deck coverings so that the average temperature on the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181 °C (325 °F) above the original temperature, within the time listed below: Class A-60 60 minutes Class A-30 30 minutes Class A-15 15 minutes Class A-0 0 minutes with no insulation requirement (c) “B” Class bulkheads. Bulkheads of the “B” Class shall be constructed with approved incombustible materials and made intact from deck to deck and to shell or other boundaries. They shall be so constructed that, if subjected to the standard fire test, they would be capable of preventing the passage of flame for one-half hour. (d) “C” Class divisions. Bulkheads or decks of the “C” Class shall be constructed of approved incombustible materials, but need meet no requirements relative to the passage of flame. (e) Steel. Where the term “steel or other equivalent metal” is used in this subpart, it is intended to require a material which, by itself or due to insulation provided, has structural and integrity qualities equivalent to steel at the end of the applicable fire exposure. (f) Approved material. Where in this subpart approved materials are required, they refer to materials approved under the applicable subparts of subchapter Q (Specifications) of this chapter, as follows: Deck Coverings 164.006 Structural Insulations 164.007 Bulkhead Panels 164.008 Incombustible Materials 164.009 Interior Finishes 164.012 (g) Stairtower. A stairtower is a stairway which penetrates more than a single deck within the same enclosure. [CGFR 65–50, 30 FR 16671, Dec. 30, 1965, as amended by CGFR 67–90, 33 FR 1015, Jan. 26, 1968; CGD 74–127, 41 FR 3845, Jan. 26, 1976; CGD 75–032, 41 FR 17910, Apr. 29, 1976]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR46-SEC-D33824
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
46 C.F.R. § 32.57.5
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
953a160d1e7d2325...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 46 C.F.R. § 32.57.5 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 46 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 46 46 C.F.R. § 32.57.5