46 C.F.R. · Shipping
46 C.F.R. § 28.360

Electrical distribution systems.

Title 46 C.F.R. ● ACTIVE Primary Source
Regulatory Text

46 C.F.R. § 28.360 — Electrical distribution systems.

§ 28.360 Electrical distribution systems. (a) Each electrical distribution system which has a neutral bus or conductor must have the neutral bus or conductor grounded. (b) A grounded electrical distribution system must have only one connection to ground. This ground connection must be at the switchboard or, on a nonmetallic vessel, at the common ground point.

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗