46 C.F.R. § 28.160

Portable fire extinguishers.

Title 46 C.F.R. ● ACTIVE Primary Source
Regulatory Text

46 C.F.R. § 28.160 — Portable fire extinguishers.

§ 28.160 Portable fire extinguishers. (a) Each vessel must meet the requirements of part 25, subpart 25.30 of this chapter. (b) Each vessel 65 feet (19.8 meters) or more in length must be equipped with the minimum number, location, and type of portable fire extinguishers specified in table 28.160. (c) Semi-portable extinguishers must be located in the open so as to be readily seen. (d) Table 28.160 of this section indicates the minimum required classification for each space listed. Extinguishers with larger numerical ratings or multiple letter designations may be used if the extinguishers meet the requirements of the table. (e) The regulations in this section have preemptive effect over State or local regulation within the same field. Table 28.160—Portable Fire Extinguishers for Vessels 65 Feet (19.8 Meters) or More in Length Space Minimum required rating Quantity and location Safety areas, communicating corridors 2–A 1 in each main corridor not more than 150 ft (45.7m) apart. (May be located in stairways.) Pilothouse 20–B:C 2 in the vicinity of the exit. Service spaces, galleys 40–B:C 1 for each 2,500 sq ft (232.2 sq m) or fraction thereof suitable for hazards involved. Paint lockers 40–B 1 outside space in the vicinity of the exit. Accessible baggage and storerooms 2–A 1 for each 2,500 sq ft (232.2 sq m) or fraction thereof located in the vicinity of the exits, either inside or outside the spaces. Workshops and similar spaces 2–A 1 outside the space in the vicinity of the exit. Machinery spaces; Internal combustion propelling machinery 40–B:C 1 for each 1,000 brake horsepower or fraction thereof but not fewer than 2 or more than 6. Electric propulsion motors or generator unit of open type 40–B:C 1 for each propulsion motor generator unit. Auxiliary spaces 40–B:C 1 outside the space in the vicinity of the exit. Internal combustion machinery 40–B:C 1 outside the space in the vicinity of the exit. Electric emergency motors or generators 40–B:C 1 outside the space in the vicinity of the exit. [CGD 88–079, 56 FR 40393, Aug. 14, 1991; 56 FR 47679, Sept. 20, 1991, as amended by USCG–2012–0196, 81 FR 48247, July 22, 2016]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR46-SEC-3B3F0F
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
46 C.F.R. § 28.160
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
9c6b3a5b4ad8d007...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 46 C.F.R. § 28.160 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 46 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 46 46 C.F.R. § 28.160