47 C.F.R. · Telecommunication
47 C.F.R. § 18.305

Field strength limits.

Title 47 C.F.R. ● ACTIVE Primary Source
Regulatory Text

47 C.F.R. § 18.305 — Field strength limits.

§ 18.305 Field strength limits. (a) ISM equipment operating on a frequency specified in § 18.301 is permitted unlimited radiated energy in the band specified for that frequency. (b) The field strength levels of emissions which lie outside the bands specified in § 18.301, unless otherwise indicated, shall not exceed the following: Equipment Operating frequency RF Power generated by equipment (watts) Field strength limit (uV/m) Distance (meters) Any type unless otherwise specified (miscellaneous) Any ISM frequency Below 500 500 or more 25 25 × SQRT(power/500) 300 1 300   Any non-ISM frequency Below 500 500 or more 15 15 × SQRT(power/500) 300 1 300 Industrial heaters and RF stabilized arc welders On or below 5,725 MHz Above 5,725 MHz Any Any 10 ( 2 ) 1,600 ( 2 ) Medical diathermy Any ISM frequency Any non-ISM frequency Any Any 25 15 300 300 Ultrasonic Below 490 kHz Below 500 500 or more 2,400/F(kHz) 2,400/F(kHz) × SQRT(power/500) 300 3 300   490 to 1,600 kHz Above 1,600 kHz Any Any 24,000/F(kHz) 15 30 30 Induction cooking ranges Below 90 kHz On or above 90 kHz Any Any 1,500 300 4 30 4 30 1  Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment operating below 1000 MHz is not permitted the increase in field strength otherwise permitted here for power over 500 watts. 2  Reduced to the greatest extent possible. 3  Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment is not permitted the increase in field strength otherwise permitted here for over 500 watts. 4  Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field strength limits for miscellaneous ISM equipment. (c) The field strength limits for RF lighting devices shall be the following: Frequency (MHz) Field strength limit at 30 meters (μV/m) Non-consumer equipment: 30-88 30 88-216 50 216-1000 70 Consumer equipment: 30-88 10 88-216 15 216-1000 20 Notes 1. The tighter limit shall apply at the boundary between two frequency ranges. 2. Testing for compliance with these limits may be made at closer distances, provided a sufficient number of measurements are taken to plot the radiation pattern, to determine the major lobes of radiation, and to determine the expected field strength level at 30, 300, or 1600 meters. Alternatively, if measurements are made at only one closer fixed distance, then the permissible field strength limits shall be adjusted using 1/d as an attenuation factor. [50 FR 36070, Sept. 5, 1985, as amended at 51 FR 17970, May 16, 1986; 52 FR 43197, Nov. 10, 1987]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR47-SEC-FCAAFF
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
47 C.F.R. § 18.305
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
796ed9de66708a57...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 47 C.F.R. § 18.305 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 47 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 47 47 C.F.R. § 18.305