43 C.F.R. · Public Lands: Interior
43 C.F.R. § 3175.94

Volume determination.

Title 43 C.F.R. ● ACTIVE Primary Source
Regulatory Text

43 C.F.R. § 3175.94 — Volume determination.

§ 3175.94 Volume determination. (a) The volume for each chart integrated must be determined as follows: V = IMV × IV Where: V = reported volume, Mcf IMV = integral multiplier value, as calculated under this section IV = the integral value determined by the integration process (also known as the “extension,” “integrated extension,” and “integrator count”) (1) If the primary device is a flange-tapped orifice plate, a single IMV must be calculated for each chart or chart interval using the following equation: ER17NO16.061 Where: C d = discharge coefficient or flow coefficient, calculated under API 14.3.3 or AGA Report No. 3 (1985), Section 5 (incorporated by reference, see § 3175.30) β = Beta ratio Y = gas expansion factor, calculated under API 14.3.3, Subsection 5.6 or AGA Report No. 3 (1985), Section 5 (incorporated by reference, see § 3175.30) d = orifice diameter, in inches Z b = supercompressibility at base pressure and temperature G r = relative density (specific gravity) Z f = supercompressibility at flowing pressure and temperature T f = average flowing temperature, in degrees Rankine (2) For other types of primary devices, the IMV must be calculated using the equations and procedures recommended by the PMT and approved by the BLM, specific to the make, model, size, and area ratio of the primary device being used. (3) Variables that are functions of differential pressure, static pressure, or flowing temperature (e.g., C d , Y, Z f ) must use the average values of differential pressure, static pressure, and flowing temperature as determined from the integration statement and reported on the integration statement for the chart or chart interval integrated. The flowing temperature must be the average flowing temperature reported on the integration statement for the chart or chart interval being integrated. (b) Atmospheric pressure used to convert static pressure in psig to static pressure in psia must be determined under appendix A to this subpart.

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR43-SEC-E71670
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
43 C.F.R. § 3175.94
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
fd38205908caaf8e...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 43 C.F.R. § 3175.94 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 43 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 43 43 C.F.R. § 3175.94