42 C.F.R. § 84.88 — Breathing bag test.

§ 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with gasoline vapor at room temperature (24–30 °C./75–85 °F.) for a continuous period of twice the rated time of the apparatus (except for apparatus for escape only where the test period shall be the rated time of the apparatus). (b) The bag will be operated during this test by a breathing machine with 24 respirations per minute and a minute-volume of 40 liters. (c) A breathing machine cam with a work rate of 622 kp.-m./min. will be used. The dimensions of a suitable breathing machine cam are available from the Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of gasoline vapor at the end of the test.

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR42-SEC-47584F
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
42 C.F.R. § 84.88
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
d439cc7573d7c429...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 42 C.F.R. § 84.88 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.