33 C.F.R. § 127.1305 — Operations Manual.
§ 127.1305 Operations Manual. Each Operations Manual must contain— (a) A description of each liquid-transfer system and vapor transfer system, including each mooring area, transfer connection, and (where installed) control room, and a diagram of the piping and electrical systems; (b) The duties of each person assigned to transfers; (c) The maximum relief-valve setting or MAWP of the transfer system; (d) The telephone numbers of supervisors, persons in charge of transfers for the facility, persons on watch in the marine transfer area for LHG, and security personnel of the facility; (e) A description for each security system provided for the transfer area; (f) A description of the training programs established under § 127.1302; (g) The procedures to follow for security violations; and (h) For each LHG handled, the procedures for transfer that include— (1) Requirements for each aspect of the transfer (start-up, gauging, cooldown, pumping, venting, and shutdown); (2) The maximum transfer rate; (3) The minimum transfer temperature; (4) Requirements for firefighting equipment; and (5) Communication procedures.