30 C.F.R. · Mineral Resources
30 C.F.R. § 75.604

Permanent splicing of trailing cables.

Title 30 C.F.R. ● ACTIVE Primary Source
Regulatory Text

30 C.F.R. § 75.604 — Permanent splicing of trailing cables.

§ 75.604 Permanent splicing of trailing cables. [Statutory Provisions] When permanent splices in trailing cables are made, they shall be: (a) Mechanically strong with adequate electrical conductivity and flexibility; (b) Effectively insulated and sealed so as to exclude moisture; and (c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket. (d) Made using splice kits accepted or approved by MSHA as flame resistant. [35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]