30 C.F.R. § 75.1400.3 — Daily examination of hoisting equipment.

§ 75.1400–3 Daily examination of hoisting equipment. Hoists and elevators shall be examined daily and such examinations shall include, but not be limited to, the following: (a) Elevators. A visual examination of the rope for wear, broken wires, and corrosion, especially at excessive strain points such as near the attachments and where the rope rests on sheaves; (b) Hoists and elevators. (1) An examination of the rope fastenings for defects; (2) An examination of safety catches; (3) An examination of the cages, platforms, elevators, or other devices for loose, missing or defective parts; (4) An examination of the head sheaves to check for broken flanges, defective bearings, rope alignment, and proper lubrication; and (5) An observation of the lining and all other equipment and appurtenances installed in the shaft. [48 FR 53239, Nov. 25, 1983]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR30-SEC-55DF0C
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
30 C.F.R. § 75.1400.3
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
4ca8c58095ed7303...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 30 C.F.R. § 75.1400.3 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 30 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 30 30 C.F.R. § 75.1400.3