30 C.F.R. · Mineral Resources
30 C.F.R. § 57.22307

Methane monitors (II-A mines).

Title 30 C.F.R. ● ACTIVE Primary Source
Regulatory Text

30 C.F.R. § 57.22307 — Methane monitors (II-A mines).

§ 57.22307 Methane monitors (II-A mines). (a) Methane monitors shall be installed on continuous mining machines, longwall mining systems, bench and face drills, and undercutting machines used in or beyond the last open crosscut. (b) The monitors shall— (1) Give warning at 0.5 percent methane; (2) Automatically deenergize electrical equipment, except power to monitoring equipment determined by MSHA to be intrinsically safe under 30 CFR part 18, and prevent starting such equipment when methane levels reach 1.0 percent; and (3) Automatically deenergize the equipment when power to a sensor is interrupted. (c) Sensing units of monitors shall be positioned at a location which provides for the most effective measurement of methane.

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR30-SEC-AC76A4
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
30 C.F.R. § 57.22307
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
5a1f842954cb66b3...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 30 C.F.R. § 57.22307 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 30 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 30 30 C.F.R. § 57.22307