30 C.F.R. · Mineral Resources
30 C.F.R. § 56.13010

Reciprocating-type air compressors.

Title 30 C.F.R. ● ACTIVE Primary Source
Regulatory Text

30 C.F.R. § 56.13010 — Reciprocating-type air compressors.

§ 56.13010 Reciprocating-type air compressors. (a) Reciprocating-type air compressors rated over 10 horsepower shall be equipped with automatic temperature-actuated shutoff mechanisms which shall be set or adjusted to the compressor when the normal operating temperature is exceeded by more than 25 percent. (b) However, this standard does not apply to reciprocating-type air compressors rated over 10 horsepower if equipped with fusible plugs that were installed in the compressor discharge lines before November 15, 1979, and designed to melt at temperatures at least 50 degrees below the flash point of the compressors' lubricating oil.

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗