14 C.F.R. · Aeronautics and Space
14 C.F.R. § 25.535

Auxiliary float loads.

Title 14 C.F.R. ● ACTIVE Primary Source
Regulatory Text

14 C.F.R. § 25.535 — Auxiliary float loads.

§ 25.535 Auxiliary float loads. (a) General. Auxiliary floats and their attachments and supporting structures must be designed for the conditions prescribed in this section. In the cases specified in paragraphs (b) through (e) of this section, the prescribed water loads may be distributed over the float bottom to avoid excessive local loads, using bottom pressures not less than those prescribed in paragraph (g) of this section. (b) Step loading. The resultant water load must be applied in the plane of symmetry of the float at a point three-fourths of the distance from the bow to the step and must be perpendicular to the keel. The resultant limit load is computed as follows, except that the value of L need not exceed three times the weight of the displaced water when the float is completely submerged: EC28SE91.042 where— L = limit load (lbs.); C 5 = 0.0053; V S 0 = seaplane stalling speed (knots) with landing flaps extended in the appropriate position and with no slipstream effect; W = seaplane design landing weight in pounds; β S = angle of dead rise at a station 3/4 of the distance from the bow to the step, but need not be less than 15 degrees; and r y = ratio of the lateral distance between the center of gravity and the plane of symmetry of the float to the radius of gyration in roll. (c) Bow loading. The resultant limit load must be applied in the plane of symmetry of the float at a point one-fourth of the distance from the bow to the step and must be perpendicular to the tangent to the keel line at that point. The magnitude of the resultant load is that specified in paragraph (b) of this section. (d) Unsymmetrical step loading. The resultant water load consists of a component equal to 0.75 times the load specified in paragraph (a) of this section and a side component equal to 0.25 tan β times the load specified in paragraph (b) of this section. The side load must be applied perpendicularly to the plane of symmetry of the float at a point midway between the keel and the chine. (e) Unsymmetrical bow loading. The resultant water load consists of a component equal to 0.75 times the load specified in paragraph (b) of this section and a side component equal to 0.25 tan β times the load specified in paragraph (c) of this section. The side load must be applied perpendicularly to the plane of symmetry at a point midway between the keel and the chine. (f) Immersed float condition. The resultant load must be applied at the centroid of the cross section of the float at a point one-third of the distance from the bow to the step. The limit load components are as follows: EC28SE91.043 where— ρ = mass density of water (slugs/ft. 2 ); V = volume of float (ft. 2 ); C x = coefficient of drag force, equal to 0.133; C y = coefficient of side force, equal to 0.106; K = 0.8, except that lower values may be used if it is shown that the floats are incapable of submerging at a speed of 0.8 V S 0 in normal operations; V S 0 = seaplane stalling speed (knots) with landing flaps extended in the appropriate position and with no slipstream effect; and g = acceleration due to gravity (ft./sec. 2 ). (g) Float bottom pressures. The float bottom pressures must be established under § 25.533, except that the value of K 2 in the formulae may be taken as 1.0. The angle of dead rise to be used in determining the float bottom pressures is set forth in paragraph (b) of this section. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-23, 35 FR 5673, Apr. 8, 1970; Amdt. 25-146, 87 FR 75710, Dec. 9, 2022]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR14-SEC-131B4C
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
14 C.F.R. § 25.535
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
9db177092b2f04bf...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 14 C.F.R. § 25.535 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 14 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 14 14 C.F.R. § 25.535