14 C.F.R. · Aeronautics and Space
14 C.F.R. § 25.1731

Powerplant and APU fire detector system: EWIS.

Title 14 C.F.R. ● ACTIVE Primary Source
Regulatory Text

14 C.F.R. § 25.1731 — Powerplant and APU fire detector system: EWIS.

§ 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless: (1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or (2) Each zone involved is simultaneously protected by the same detector and extinguishing system. (c) EWIS that are part of each fire or overheat detector system in a fire zone must meet the requirements of § 25.1203.

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR14-SEC-583B22
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
14 C.F.R. § 25.1731
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
c7a899e488ecba5c...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 14 C.F.R. § 25.1731 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.