14 C.F.R. · Aeronautics and Space
14 C.F.R. § 25.103

Stall speed.

Title 14 C.F.R. ● ACTIVE Primary Source
Regulatory Text

14 C.F.R. § 25.103 — Stall speed.

§ 25.103 Stall speed. (a) The reference stall speed, V SR , is a calibrated airspeed defined by the applicant. V SR may not be less than a 1-g stall speed. V SR is expressed as: ER26NO02.001 where: V CL MAX = Calibrated airspeed obtained when the load factor-corrected lift coefficient ER26NO02.002 is first a maximum during the maneuver prescribed in paragraph (c) of this section. In addition, when the maneuver is limited by a device that abruptly pushes the nose down at a selected angle of attack (e.g., a stick pusher), V CL MAX may not be less than the speed existing at the instant the device operates; n ZW = Load factor normal to the flight path at V CL MAX W = Airplane gross weight; S = Aerodynamic reference wing area; and q = Dynamic pressure. (b) V CL MAX is determined with: (1) Engines idling, or, if that resultant thrust causes an appreciable decrease in stall speed, not more than zero thrust at the stall speed; (2) Propeller pitch controls (if applicable) in the takeoff position; (3) The airplane in other respects (such as flaps, landing gear, and ice accretions) in the condition existing in the test or performance standard in which V SR is being used; (4) The weight used when V SR is being used as a factor to determine compliance with a required performance standard; (5) The center of gravity position that results in the highest value of reference stall speed; and (6) The airplane trimmed for straight flight at a speed selected by the applicant, but not less than 1.13V SR and not greater than 1.3V SR . (c) Starting from the stabilized trim condition, apply the longitudinal control to decelerate the airplane so that the speed reduction does not exceed one knot per second. (d) In addition to the requirements of paragraph (a) of this section, when a device that abruptly pushes the nose down at a selected angle of attack (e.g., a stick pusher) is installed, the reference stall speed, V SR , may not be less than 2 knots or 2 percent, whichever is greater, above the speed at which the device operates. [Doc. No. 28404, 67 FR 70825, Nov. 26, 2002, as amended by Amdt. 25-121, 72 FR 44665, Aug. 8, 2007]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR14-SEC-6EA62C
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
14 C.F.R. § 25.103
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
bbe1fd543a043238...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 14 C.F.R. § 25.103 is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 14 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 14 14 C.F.R. § 25.103