Acceptance criteria for reactor coolant system venting systems.

Title 10 C.F.R. ● ACTIVE Primary Source
Regulatory Text

10 C.F.R. § 50.46a — Acceptance criteria for reactor coolant system venting systems.

§ 50.46a Acceptance criteria for reactor coolant system venting systems. Each nuclear power reactor must be provided with high point vents for the reactor coolant system, for the reactor vessel head, and for other systems required to maintain adequate core cooling if the accumulation of noncondensible gases would cause the loss of function of these systems. High point vents are not required for the tubes in U-tube steam generators. Acceptable venting systems must meet the following criteria: (a) The high point vents must be remotely operated from the control room. (b) The design of the vents and associated controls, instruments and power sources must conform to appendix A and appendix B of this part. (c) The vent system must be designed to ensure that: (1) The vents will perform their safety functions; and (2) There would not be inadvertent or irreversible actuation of a vent. [68 FR 54142, Sept. 16, 2003]

Source: ecfr.gov · govinfo.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-CFR10-SEC-D4E8FE
Entity Class
REGULATION / FEDERAL-CFR-SECTION
Domain Signature
boisestandard.org
Citation
10 C.F.R. § 50.46a
Corpus
CFR — Code of Federal Regulations
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
1167b9fa9358a32c...
Semantic Edges
Pending — corpus passes queued
The regulatory text of 10 C.F.R. § 50.46a is reproduced from the official Code of Federal Regulations as published by the Office of the Federal Register and the National Archives and Records Administration.
Navigate Corpus — Title 10 C.F.R.
◈ Provenance
boisestandard.org United States Law CFR Title 10 10 C.F.R. § 50.46a