Idaho Code · Title 61 · Public Utilities
Idaho Code § 61-802

Definitions

Ch. 8 — STRAY CURRENT AND VOLTAGE REMEDIATION ACT
Idaho Code ● ACTIVE State Law Title 61
Statutory Text

Idaho Code § 61-802 — Definitions.

TITLE 61 PUBLIC UTILITY REGULATION CHAPTER 8 STRAY CURRENT AND VOLTAGE REMEDIATION ACT 61-802. Definitions. As used in this chapter, unless the context otherwise requires: (1)  "Adequate remediation" means corrective action by a utility which results in, and is reasonably likely to sustain, a reduction of stray current or voltage attributable to the utility’s distribution system of fifty percent (50%) or less of the preventive action level. (2)  "Commission" means the Idaho public utilities commission as established pursuant to section 61-201 , Idaho Code. (3)  "Cow contact points" means any two (2) electrically conductive points which a dairy cow may, in its normal environment, unavoidably and simultaneously contact. (4)  "Preventive action level" is stray current or voltage that is either: (a)  A steady-state, root mean square (rms), alternating current (AC) of 2.0 milliamp (mA) or more through a 500 ohm resistor connected between cow contact points, as measured by a true rms meter; or (b)  A steady-state, rms, AC voltage of 1.0 volts or more, across (in parallel with) a 500 ohm resistor connected between cow contact points, as measured by a true rms meter. (5)  "Steady-state" is the value of a current or voltage after an amount of time where all transients have decayed to a negligible value. (6)  "Stray current or voltage" is: (a)  Any steady-state, 60 hertz (Hz) (including harmonics thereof), root mean square (rms), alternating current (AC) of less than 20 milliamp (mA) through a 500 ohm resistor connected between cow contact points, as measured by a true rms meter; or (b)  Any steady-state, 60 Hz (including harmonics thereof), rms, AC voltage of less than 10 volts, across (in parallel with) a 500 ohm resistor connected between cow contact points, as measured by a true rms meter. Stray current or voltage is a normal, inherent and unavoidable result of electricity traveling through grounded electrical systems, including a dairy producer’s on-farm system and a utility’s distribution system, which systems are required by the national electrical code and the national electrical safety code to be grounded to the earth to ensure continuous safety and reliability. (7)  "Utility" means a public utility as defined in section 61-332A , Idaho Code.

History:[61-802, added 2005, ch. 189, sec. 1, p. 578.]
Source: legislature.idaho.gov — public domain Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record Root-LD v1.0 · boisestandard.org
Federation ID
BS-IC61-SEC-B654A5
Entity Class
STATUTE / IDAHO-STATE-CODE-SECTION
Domain Signature
boisestandard.org
Jurisdiction
Idaho — United States
Citation
Idaho Code § 61-802
Status
✓ ACTIVE
Source
PRIMARY-SOURCE
Source Verified
✓ TRUE
Content Hash
631ff03881fc8d5a...
Semantic Edges
Pending — corpus passes queued
The statutory text of Idaho Code § 61-802 is reproduced from the official Idaho Legislature website (legislature.idaho.gov), published by the Idaho Legislative Services Office. Idaho Code is public domain.
Navigate Corpus — Idaho Code Title 61
◈ Provenance
boisestandard.org United States Idaho Idaho Code Title 61 Idaho Code § 61-802