Ordinance Text
9-1A-54: IBC BUILDING CODE AMENDMENT, SECTION 1605.3.1, BASIC LOAD COMBINATIONS, ADD EXCEPTION 6:
Add exception 6 to section 1605.3.1 as follows:
6. In Equation 16-10, the snow load S shall be calculated using pm as defined in Section 1608.1. For other load combinations involving snow loads, S shall be calculated using flat roof snow load (pf) or sloped roof snow load (ps) as defined in ASCE 7.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
Source: American Legal Publishing — codelibrary.amlegal.com — public domain
Official Source ↗
Root-LD Entity Data
◈ Machine-Readable Provenance Record
boisestandard.org · municipal corpus
Federation ID
bs-aml-boi-b399f632081e59ee
Doc ID
0-0-0-36922
Domain Signature
boisestandard.org
Jurisdiction
Boise, Idaho — United States
City
Boise
County
Ada County
Publisher
American Legal Publishing
Source Verified
✓ TRUE
Navigate — Boise City Code of Boise City
← 9-1A-53: IBC BUILDING CODE AMENDMENT, SECTION 1605.2, L
9-1A-55: IBC BUILDING CODE AMENDMENT, SECTION 1608.1, S →
Nearby Sections
9-1A-49: IBC BUILDING CODE AMENDMENT, SECTION9-1A-50: IBC BUILDING CODE AMENDMENT, SECTION9-1A-51: IBC BUILDING CODE AMENDMENT, AND SEC9-1A-52: IBC BUILDING CODE AMENDMENT, SECTION9-1A-53: IBC BUILDING CODE AMENDMENT, SECTION9-1A-54: IBC BUILDING CODE AMENDMENT, SECTION9-1A-55: IBC BUILDING CODE AMENDMENT, SECTION9-1A-56: IBC BUILDING CODE AMENDMENT, SECTION9-1A-57: IBC BUILDING CODE AMENDMENT, SECTION9-1A-58: IBC BUILDING CODE AMENDMENT, SECTION9-1A-59: IBC BUILDING CODE AMENDMENT, SECTION9-1A-60: IBC BUILDING CODE AMENDMENT, SECTION9-1A-61: IBC BUILDING CODE AMENDMENT, TABLE 29-1A-62: IBC BUILDING CODE AMENDMENT, TABLE 29-1A-63: IBC BUILDING CODE AMENDMENT, SECTION
Boise Municipal Code — public domain
← Boise Code Index